DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1168UDS1-BD (UDS1 Interface Circuit Pack)
3
LEDs
The LEDs on the faceplate of the TN2242 circuit pac k indicate its status as
described in Table 3-512.
Interactions with other MOs
The TN2242 maintenance object direc tly interacts with these maintenance
objects:
‘‘Synchronization’’
‘‘TN2242 trunk ports’’
‘‘Call processing’’
Synchronization
The DS1 facility plays a vital role in the synchronization subsystem. The
Tone/Clock circuit pack uses either the p rimary or secondary timing reference,
whether internal (local -- Tone/Clock circuit p ack) or external. TN2242 circuit
packs can b e administered as “prim ary” or “second ary” synchronization
references.
TN2242 circuit pack send s DS1 link status information to the synchronization
reference switching alg orithm that determines whether timing referenc es should
be switched d ue to failure or restore conditions.
TN2242 trunk ports
The TN2242 circuit pack MO is respon sible for monitoring the health of the DS1
facility. If a DS1 facility goes down, then that fac ility’s DS1 circuit pack instruct s
all DS1 port MOs associated with the fac ility to place their trunks (or ISDN-PRI
signaling link) in an out-of-servic e sta t e.
Call processing
The busyout board command tears down all c alls and signaling links associated
with a TN2242 circuit pack.
Table 3-512. TN2242 LED interpretation
LED Meaning
Red MAJOR alarm
MINOR alarm
Firmware initialization during circ uit pack insertion
Yellow A port on the circuit p ack is in use.
Green Maintenance testing is in progress on the circuit pack or
its ports.