DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-248ATM-TRK (Circuit Emulation Service Circuit Pack)
3
Table 3-108. ATM Board Error Query Test (#1259)
Error
Code
Test
Result Description/ Recommendation
2000 ABORT Test request timed out.
2031 ABORT SCD failure. Unable to sent down-link message.
2100 ABORT Could not allocate needed system resources.
2500 ABORT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
XXYY FAIL On-board error XX (Table 3-109) and/or off-board error YY (Table 3-110).
1. Examine the error logs and repair any errors found.
PASS The ATM circuit pack has passed this test. No service effecting
errors/alarms have been detected on board.
0NO
BOARD ATM-TRK circuit pack not found
1. Check the error log, and correct Error 125 (wrong board) or Error 131
(no board), if found.
2. Make sure that the board is properly translated and inserted.
3. Check for hyperactivity (Error 1538). Run reset board UUCSS if
hyperactive.
4. Run the test again. If it fails, replace the board, and retest.
Continued on next page