DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1092TIE-DS1 (DS1 Tie Trunk)
3
Notes:
a. Error Type 1The DS1 Interface circuit pack de tects a hardware error on
the DS1 tie trunk. This error can be caused b y incompatible translations.
Make sure the parameters administered on the DS1 circuit pack form
match those administered on the far-end switch.
The Aux Data field indicates the following hardware error types:
If all administration errors between the switc h and the far-end matc h, and
these errors continue to recur, follow normal escalation proced ures.
b. Error Type 15This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate
associated errors (if any).
c. Error Type 18The DS1 tie trunk has been busied out by a busyout trunk
grp/mbr com mand. No calls can b e made on this trunk excep t for the
Facility Access Test Call.
d. Error Type 130This error type indicates that the circuit pa ck has been
removed or has been insane for more than 11 minutes . To clear the error,
reinsert or rep lace the circuit pack.
e. Error Type 257The DS1 Interface circuit pack d etects a hardware error
on the DS1 tie trunk. The trunk cannot communicate with the far end
because it is unable to inte rpret digits sent from the far-end switch. The
Aux Data field indicates the following:
Check with the far-end switc h or operating comp any for proper trunk
connection.
f. Error Type 513DS1 Interface circuit pac k detects a hardware error on
the DS1 tie trunk. The trunk is in-service/active and waitin g for an
‘‘on-hook’’ from the far-end switch. No calls c an be routed over the trunk
while it is in this state. Aux Data 57392 indic ates no external release on
PBX disconnect. Check with the far-end switch or operating company for
proper trunk connec tion.
g. Error Type 769—The DS1 Interface circuit p ack detects a hard ware error
on the DS1 tie trunk. This error usually occurs after one or more
occurrences of error typ e 513. The trunk has received the belated
57476 On-hook before wink
57477 On-hook before ready to rec eive digits
57485 Wink too short for valid signal
57487 The timer expired while waiting for an off-h ook
signal from the far end as a resp onse at end of
digits dialing . Check the far-end switch for related
problems.
57473 The rotary dial rate is below 8 pulses p er second.
57474 The rotary dial rate is above 12 pulses p er second.