DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-590DS1-BD (DS1 Interface Circuit Pack)
3
Table 3-246. TEST #145 Misframe Alarm Inquiry Test
Error
Code Test Result Description/ Recommendation
ABORT Internal system error
2100 ABORT Could not alloca te the nec essary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of servic e and one or more
of the following symptoms may appear.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows th at the circuit pac k and the ports are
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the
system, and all of the trunks for this circuit pack are placed into the
out of service state. The system will try to restore the circuit pack
within 15 minutes. When no faults are detected for 15 minutes, the
DS1 interface circuit pack is restored to normal operation. All of the
trunks for the DS1 interface circuit pack are then returned to the in
service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms) would
be entered in the error log. In addition, many hardware errors would
be logged against the associated trunk c ircuits. If the facility is OK
and the error occurs again after 15 minutes, escalate this problem.
Continued on next page