DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-643ERR-LOG (Error Log)
3
ERR-LOG (Error Log)

Functional Description

The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware
Error Log, and the Software Error Log. If an inconsistency is d etected in any one
of these logs, all logs are re-initialized and a hardware error is logged against
ERR-LOG indicating the time of inconsistenc y. There are no tests and no alarms
for the Error Log MO. This MO exists solely for the purpose of allowing errors to
be logged against it.

Hardware Error Log Entries and Test to Clear

Valu es
Notes:
a. This error indicates that an inconsistenc y was detected in either the Alarm
Log, the Hardware Error Log, or the Software Error Log. To recover from
this error, all of the logs were cleared and re-initialized. Any alarms that
were active at the time of this error have been c leared. There is no
associated test for this error.
The Aux data value indicates when the inconsistency was found:
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run Full Name of MO
ERR-LOG none none Error Log
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to
the appropriate test description and follow the recommended procedures.
Any Any Any Any none
510 (a) Any none none none none
0 Found during a periodic audit of the Error Log
1 Found after an extended reboot
2 Found after a reboot
3 Found after a Reset System 3 (Cold_1)
4 Found after a Reset System 2 (Cold_2)
16 Found after a Warm Start
100 Found after an internal software audit