DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-648ETH-PT (Control LAN Ethernet)

3
Ethernet Local Looparound Test (#1278)
This test is destructive.

Use this test to check circ uitry in the data path for an Ethernet c all (from the

on-board processor t o the Ethernet Transceiver). This test fails if the data it

receives does not match the d ata it transmits.

Table 3-268. TEST #1278 Ethernet Local Looparound Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT The port is in use.
1. Determine status of p ort (status clan-port UUCSSpp).
2. Retry the command when the port is idle. The post may be forced to the
idle state by executing a busyout port UUCSS command.
NOTE:
The busyout port command is destructive, causing all calls and links
associated with the port to be torn down.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circ uit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, escalate the problem.
2100 ABORT Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1 FAIL Circuit pack detected failure in the Ethernet Local Looparound Test (#1278).
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and reset board UUCSS).
2. If the problem persists, replace the circ uit pack.
PASS The circuitry tests properly.
Continued on next page