DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-521DIG-LINE (Digital Line)
3
Table 3-220. TEST #17 Station (Digital) Audits Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT Switchhook audit timed out.
2 ABORT ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3 ABORT The EPF/PTC has detected an overcurrent c ondition.
1. For a TN754 vintage 13 or earlier Digital Line circuit pack, issue the
test PCSSpp long command. If Test #11 passes, then the EPF/PTC
condition has been cleared. Rerun the Short Test Sequence. If Test
#11 does not pass, follow the repair procedures described for Test
#11.
2. Look for Error Type 769 logged against DIG-LINE and follow the
procedures in the associated footnote. If any additional problems are
found after completion of maintenance procedures, rerun the test.
4 ABORT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals a maximum of 5 times.
5 ABORT Ringer update aborted due to station being in ready-for-servic e or
out-of-service state.
6 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, the release the port via the release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port com mand
(the display shows that the port is a TTI port) or the list config
command (the display shows a t for the port).
2. If either list config or display port indicate that the port is
not
a TTI
port, escalate the problem. If both commands indic ate that the port is
a TTI port, the abort is correct, and no action is necessary.
Continued on next page