DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-524DIOD-DS1 (DS1 DIOD Trunk)

3
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Hardware Error Log Entries and Test to Clear
Valu es
out-of-service The trunk is in a deactivated state an d cannot be used for either incoming or outgoing calls.in-service The trunk is in an activated state and can be used for both incoming and outgoing calls.disconnect (ready-for-service) The trunk is in an activated state b ut can only be used for an incoming c all.
Table 3-221. DS1 DIOD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
010 Any Any Any test trunk <grp>/<mb r>
1(a) 57408
1(a) 57487
57476
57477
57485
15(b) Any Port Audit an d
Update Test (#36)
18(c) 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk < grp>/ <mbr>
130(d) None WARNING ON test trunk <grp>/< mbr>
257(e) 57392 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2OFF
513(f) 57393 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2OFF
769(g) 57484
1025(h) 51200
1025 DS1 CO Dial Tone
Seizure Test (#314) MIN/
WRN3OFF test trunk <grp>/<mbr> r 2
1281 Conference Circuit
Test (#7) MIN/
WRN3ON test trunk <grp>/<mbr> l r 4
1537 NPE Crosstalk Test
(#6) MIN/
WRN3ON test trunk <grp>/<mbr> l r 3
1793(i) test board PCSS l
Continued on next page