DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-465DID-DS1 (DS1 DID Trunk)
3
1004 ABORT The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
1020 ABORT The test did not run due to a previously existing error on the specific port
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281Loss of signal, 1793Blue Alarm, 2049Red Alarm, 2305Yell ow
Alarm, 1537Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the l isted error types.
ANY FAIL The test failed. This can be due to on-board or off-board problems.
Off-b oard p roblem s of con cern inc lude EXP- PN and EXP-IN TF faults,
TDM-BUS faults, and faults associated with the tone detectors/tone
generators. Clear all off-board problems before rep lacing the board. Keep
in mind that a TDM-BUS problem is usually the result of a faulty board
connected to the backplane or bent p ins on the backplane.
1. Look for EXP-PN and/or EXP-INTF errors in the error log. If present,
refer to the EXP-PN and the EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentatio n.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present,
refer to the TONE-BD and the TONE-PT Maintenance documentation.
4. Retest when the faults from steps 1, 2, and 3 are cleared. Replace the
board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated using other port tests and by
examining station, trunk, or exte rnal wiring.
Table 3-197. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page