DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-134Unusual ATM trouble conditions
1
Action
1. Correct the ATM addresses (or swap fibers) on the A5 00 between the
inco rrec tly-c onn ecte d PPN an d EPN.
Swapped Routes, End System Identifiers, or Fiber
between two EPNs
Symptoms
All TN230Xs complete board inser tion.
The PPN cold starts both incorrectly c onnected EPNs as usual.
Both EPNs log many WRONG BOARD INSERTED errors (use list
configuration all or display circuit-packs
<carrier>
) providing the EPNs
actually do have different b oards configured in the same slots.
Some end stations may work if they are connected to the correct board in
the same slot on both EPNs. Otherwise, end stations on th e PPN have dial
tone, while end stations on the EPNs do not.
All A500 diagnostic c ommands look good .
Diagnostics
1. Check log for WRONG BOARD INSERTED errors (use list configuration all
or display circuit-packs
<carrier>
).
Action
1. Correct the ATM addresses (or swap fibers) on the A5 00 between the
incorrectly connec ted EPNs.
Swapped Routes, End System Identifiers, or Fiber
between A and B side TN230Xs on an EPN
Symptoms
The PPN establishes links to what it thinks is the active TN230X on the
EPN.
As normal, it reboots this TN230X, and when comp lete, it resets the EPN.
When this happens, the active (instead of the standby) TN230X reboots,
dropping the links.
To recover, the PPN re-establishes links to what it thinks is the active
TN230X and the cycle repeats ind efinitely.