DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-41disable synchronization-switch
2
disable synchronization-switch
This command stops the automatic clock switching capability of the mai ntenance
subsystem. The clock refers to the osc illator on a tone/ clock or DS1 interfac e.
The synchronization subsystem (TDM bus c lock, DS1 trunk board, and
maintenance and administr ation software) provides error-free digi tal
communication between the switch and other PBXs, COs, or customer
equipment.
disable test-number
The disable test-number command prohibits selected maintenance tests from
running. To run a disabled test number, enter the enable test-nu mber comman d.
display alarms
The display alarms c ommand creates an Alarm Report. The user c ompletes an
option screen to select the p arameters for the report.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
synchronization-
switch
init
inads
craft
none none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
test-number
number
print
schedule
Maintenance test number
Report sent to printer
Command is validated and then a
scheduling form disp lays to
schedule execution of the
command. The command is then
placed in the command q ueue
and is executed at the spec ified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.1
Examples:
disable test-number 710
disable test-number 710 print
disable test-number 510
schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads none none