DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-251ATM-TRK (Circuit Emulation Service Circuit Pack)

3
back to a digi tal counter and sends it to the tone receiver for verification. If the circuit pack p asses the circuit c heck, the software checks the packet path b y sending a pac ket from the packet-interfac e circuit pack to the ATM-TRK circuit pack via the ATM protocol stack. Figure 3-174 and Figure 3-175 show a diagrams of this two-part test, substituting “CES mode” for “PNC mode.”
Table 3-111. ATM Board Framer Looparound Test (#1260)
Error
Code
Test
Result Description/ Recommendation
1002 ABORT Time slots could not be allocated. Traffic may be heavy or time slots may be
out-of-service.
1. Run display errors, and perform repairs associated with TDM-BUS
errors.
2. Retry the command up to 3 times at 1-minute intervals.
1003 ABORT Tone receiver could not be allocated.
1. Run display errors, and perform the repairs associated with TTR-LEV
and TON E-PT errors .
The test cannot run unless there is at least one Tone Detector available on
the network that holds the ATM-TRK circuit pack.
2. Retry the command up to 3 times at 1-minute intervals.
1015 ABORT ATM-TRK circuit pack not busied out
1. Busyout the ATM circuit pack.
2. Rerun the command .
1033 ABORT ATM-TRK circuit pack not found
1. See if the switch can see the circuit pack. Run status Trunk Group.
2. Retry the command.
1139 ABORT Major alarm on the EPN packet bus
1. Run display alarms, and perform the repairs associated with PKT-BUS
errors.
2. Run display errors, and perform the repairs associated with PKT-BUS
errors.
3. Retry the command.
1141 ABORT Packet-interface circuit pack out of service
1. See PKT-INTF.
Continued on next page