DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-468DID-DS1 (DS1 DID Trunk)
3
1018 ABORT The test was disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’
screen is set to ’n’. To enable the test, change the trunk administration
and enter ’y’ into the ’Maintenance Test’ field.
2. Repeat the test.
1020 ABORT The test did not run due to a previously existing error on the spec ific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not alloc ate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pac k: 1281
Loss of signal, 1793Blue Alarm, 2049Red Alarm, 2305Yellow Alarm,
1537Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Table 3-198. TEST #7 Conference Circuit TestContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page