DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-445DATA-CHL (Data Channel)
3
Table 3-189. TEST #111 Data Channel Local Loop Back Test
Error
Code
Test
Result Description/Recommendation
4 ABORT For this test, an Error Code of 4 can have one of two different meanings:
b. The target DATA-CHL is busy and, therefore, not availab le for use.
c. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Jou rnal P r inter Link, PMS Link, or secondary
administration terminal connection) as described previously in the ‘‘Status
of Data Channels’’ section. If so, check for errors on the function that is
using the DATA-CHL. If there are no errors, there is a high probability that
the DATA-CHL is not defective. Proceed with the remaining steps only if it
is necessary to completely test the target DATA-CHL.
1. If the target DATA-CHL is in use for some other function, busyout the
funct ion (PRI- CDR/SEC-C DR, SYS-PRNT, PMS- PRNT/JNL- PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Rest ore any busie d out PRI- CDR/SEC-C DR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
40
70
75
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page