DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1125TIE-TRK (Tie Trunk)
3
1115 ABORT The near end test line on the circuit pack could not be allocated .
1. Verify that the circuit pack is in service and that port 1 is administered
and in service with the status port command.
2. retry the command at 1-minute intervals for a maximum of 5 retries.
1900 ABORT The test completion message was not received from the circuit pack.
1. Test the TN798 circuit packs.
1901 ABORT This error occurs when the TN798 circuit pack uplinks a message that is
not the proper response for this test. The anticipated uplink messages are
seize, ring or answer.
1. Verify that the Trunk is administered properly.
1905 ABORT Intercept tone detected from far end.
1. Get the test line data from theand verify it with the far end. Dial the test
number manually to see if the TTL is reached. If it is not, then eithe r t he
number is wrong, or the far end is administered inco rrectly.
1906 ABORT Reorder tone detected from far end.
1. See actions for error cod e 1905.
1907 ABORT Other unexpected tone detected from far end.
1. See actions for error cod e 1905.
1913 ABORT Audible Ring detected from far end.
1. See actions for error cod e 1905.
1914 ABORT Unidentified interrupted tone detected from far end .
1. See actions for error cod e 1905
1915 ABORT Busy tone detected from far end.
1. Since the test line at the far end was busy. Try the test again.
2. If the test continues to abort, the problem is with the far end system.
1918 ABORT Test progress tone not removed from far end (type 105 t est line only).
1. The problem is with the far end system; a technician at the far end
should test the test line (TN798).
1919 ABORT Unexpected far end release
1. The problem is with the far end system; a technician at the far end
should test the test line (TN798).
Table 3-496. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page