DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-852MMI-SYNC
3
If the MMI circuit pac k that provides synchronization is c raft busied out, it will not
affect the PN synchronization. The signal is still p rovided by the b usied-out pack.
There is no affect on synchronization if the technic ian issues a release of the
busied-out MMI. Synchronization is not affec ted by a warm start of the syst em
(reset system 1). For all other restarts (reboot through cold 2), MMI
synchronization recovers du ring board insertion.
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
There are no system technician-demanded tests for MMI-SYNC.
Table 3-369. MMI-SYNC Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 Any None See note 1
1. An MMI synchronization switch was succ essful. Refer to MMI-BD errors for the reason for the
switch.
257 Any None MINOR OFF See note 2
2. The requested MMI synchronization switch failed. Resolve all MMI-BD alarms.