DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-323CABINET (Cabinet Sensors)
3
1FAIL
(cont’d.)
There is a problem with the environm ent of the power system:
7. The power unit could be defec tive. Refer to the ‘‘Removing Power’’
and ‘‘Restoring Power ’’ sections in Chapter 1, ‘‘Maintenance for csi
systems’’.
a. If the yellow LED is off, replace the power unit.
b. If the Ac tive Tone-Clock circuit pack loses power, the system
performs a Cold-2 restart to finish (the login prompt appears at the
administration terminal).
c. Rerun the test.
PASS There is neither a power nor fan a problem in any of the cabinets. If a
problem is reported, troubleshoot by using the p rocedures for the FAIL
cases describ ed previously.
Table 3-140. TEST #122 Cabinet Temperature Query TestContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page