DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-58ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)

3
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telep hone equipment, sig naling, rotary dial pulsing, transmission, and balanc e. This test checks the signal ing and switchhook capab ilities of the battery feed c hip by terminating the port, applying battery, and trying to detec t a current.
PASS The port is correctly using its allocated time slots. User-reported troubles
on thi s port sh ould be in vestigated by us ing other port tests, by exami ning
station wiring, by examining the station, and by ensuring that the terminal
is correctly translated as off-premises or on-premises.
NOTE:
This test always passes for Analog circuit packs TN742 prior to
Vintage 4.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command and resolve any problems.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-24. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page