DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-228status bri-port
2
status bri-port
This command display s the service state, maintenance state and layer 1 state of
an ISDN-BRI port. This form also displays information ab out point-to-point
signaling links that transp ort over the port.
Output
For the following example shows the output from th e status bri-port 1c1701
command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status bri-port
location
print
Port location: PCSSpp
Report sent to printer
init
inads
craft
cust
nms
browse
none none
Port: ISDN-BRI port address.
Service State: ISDN-BRI port is “in-service” or “ out-of-service.”
Maintenance Busy?: specifies if maintenance tes ting is executing on the ISDN-BRI
port (“yes” or “ no”).
status bri-port 1c1701 Page 1 of 1 SPE A
STATUS BRI-PORT
Port: 01C1701
Service State: in-service
Maintenance Busy?: no
Layer 1 State: activated
TEI Value Layer2 State Endpt Extension Endpt SPID Service SPID?
Link1 64 13-established 1010 1010
Link2
Link3