Maintenance Commands
2-343test hardware-group
2
Setting the Test Parameters
Once the user has entered the des ired action (test hardware-group) and the
object (board, c arrier, etc.), then an options form displays.
Field descriptions
Test
sequence

Short

(nondestructive) or

long

(more comprehensive, still
nondestructive) test sequenc e
Test
Repetition

repeat

- (1-99) each test is executed the number of times specifie d on
each physical ob ject.

continuously

-all tests on all the specified hardware run until
cancelled b y either pressing the CANCEL key or b y executing the
cancel hardware-group command.
count: Repeat test sequence value (1-99). If the Test sequence fie ld is set
to continuously, then this field disappears from the screen; if this field
is set to repeat, then the field appears.
Auto-page? Provides a new screen every time the SAT screen fills with test results.
(
n
/
y
). The screen does not scroll to ac commodate new results;
instead a new screen is p rovided after the curren t screen fills up.
If the

auto-page

option is not selected, th e SAT screen does not
refresh once it is filled, and testing stops until the user ente rs the PAGE
key to continue or the CANCEL key to cancel the testing.
This option is not allowed if the
background
option is selected.
test hardware-group system Page 1 of 1
TEST HARDWARE-GROUP SELECTIONS
Select the desired options for the specified test.
Test sequence: short
Test repetition: repeat count: 1
Output OPTIONS: HARDWARE OPTIONS:
Auto-page? n All-ports? n
Background? n SPE-interchange? n
Failures? n