DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-825MET-LINE (MET Line)
3
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to d etermine the
station extension, attendant number, or trunk group/member number of
the port. Use the status station, status attendant, or status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting. Attendants
are always in use (off-hook) if the handset is plugged in and the port is
not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2012 ABORT Internal System Error.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 FAIL The conference circuit test failed. The conference c ircuit test is
performed only if the hybrid test passes. The conference circuit test
verifies that the network processing element (NPE) is able to correctly
conference several test tones together. The test is executed in two
parts. The first half of the test verifies the operation of the NPE’s first
three conference channels, while the second half verifies the NPE’s
remaining four conference channels. The test puts the NPE in loop
around mode and instructs it to talk on a specified time slot while
listening to a 1004 Hz tone, using the conference channels. A GPTD
then measures the signal and noise levels of the conferenced output
and reports whether or not these are within an acceptable range. The
failure may be due to off-board circumstances, the most common of
which is an off-hook occurring during the test. It is possible that the port
may still be functional from a user’s point of view. Also, check the error
logs against the GPTD-BD, the TONE-BD, and the TONE-PT.
1. This error can be caused by a disconnec ted terminal. First, ensure
that the terminal is connected and the wiring is OK.
2. Then, issue the display port and the station status commands to
determine if the station is idle. If it is idle, issue the test port
command for this port.
3. If test continues to fail, issue the busyout port and the release
port commands, and then retest the port.
Table 3-357. TEST #57 MET Circuit and Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page