DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-90display test-schedule
2
Test Type One of the following types of test to b e performed on the trunk
group/members in this schedule:
full (default) runs the most comprehensiv e test and collects all
associated measurements for eac h TTL type.
supv performs a supervision test and only confirms the
presence of the test set at the far end . No measurements are
taken for this test.
no-st runs the "full" test, but skips any self-test sequences. This
saves about 20 seconds on the type 105 test and doe s not
have any effect on type 100 or 102 tests.
no-rl runs the "full" test, but skips any return loss sequences.
This saves about 20 seconds on the type 105 test and does not
have any effect on type 100 or 102 tests.
no-st/rl runs the "full" test, but skips all self-test and return loss
sequences. This saves about 40 sec onds on the type 105 test
and does not have any effect on typ e 100 or 102 tests.
Duration The maximum number of hours (1 to 24) a schedule c an remain
active. Schedules contin ue to run until all trunk group/members for
that particular sc hedule are tested or until the sche dule duration is
reached. If the duration is reac hed before all trunk
groups/members c an be tested, the sched ule stops.
Trk Trp The trunk group numbers to be tes ted when this schedule runs.
There is no limit to the number of times that a trunk group can
appear on any partic ular schedule, or to the numb er of different
schedules in which a trunk group can app ear. Default is blank.
Bgn Mbr The beginning member numb er of the trunk group to be te sted;
default is 1.
End Mbr The ending member number of the trunk group to be tested . This
value must be greater than or eq ual to the value of the beginning
member field.