DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-120ANN-PT (Announcement Port)
3
FAIL Test failed. Announcements cannot be played back over this port.
1. Reset the circuit pack via the reset board PCSS command and then
run this test again. If the test continues to fail, replace the circuit pack
(see Warning).
2. If there are recurring alarms on this port caused by this test failing,
replace the circuit pack even if Step 1 works (see Warning).
!WARNI NG:
Replacing the circuit pack results in loss of integrated
announcements. Refer to ‘‘General Notes’’ near the beginning of this
Maintenance procedure.
PASS Announcements can be played bac k over this port. User-reported troubles
on this pack should be investigated using other port and circuit pack tests.
Refer to the ‘‘ANN-BD (Announcement Circuit Pack)’’ Maintenance
documentation for a description of the circuit p ack tests.
Table 3-46. TEST #222 140AY Channel Sanity Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page