DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-123ANNOUNCE (Announce)

3
Aux Data Error Codes and Recommended Repair Procedures
Table 3-48. Aux Data Error Codes and Recommended Repair Procedures
Aux
Data Description/ Recommendation
9000
through
9031
CARD-MEM errors
Check and resolve CARD-MEM errors and alarms.
32001 Internal system error.
1. Check other ANNOUNCE errors and take corrective action. If there are no other
ANNOUNCE errors, do the following:
2. Retry the command at 2-minute intervals a maximum of 3 times.
3. If the save/restore announcements command fails, escalate the problem.
32002 Announcement circuit pack is in use.
1. Retry the command at 2-minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the problem.
32003 Announcement po rt is in use.
1. Wait for all Announcement ports to become available.
2. Enter the save/restore announcements command.
32004 There are no announcements recorded on the Announcement Circuit Pack. The save
announcements command is not allowed to prevent the destroying of the
announcement file on tape [286 systems] or on the memory card [386 systems].
32005 Integrated announcement circuit pack is not p resent. The Announcement Circuit Pack
is not inserted, or it is defective.
1. Enter the list config command to check for the presence of the circuit pack in the
system.
2. If the Announcement Circuit Pack is present, use the test board PCSS command
to check the status of the Announcement Circuit Pack.
32006 Announcement Data Module not available.
1. Use the status command to check the status of the Announcement Data Module.
32007 Announcement Data Module out of service.
1. Use the status command to check the status of the Announcement Data Module.
32008 Announcement data is being saved or loaded.
1. Retry the command at 2-minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the problem.
Continued on next page