DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-654ETH-PT (Control LAN Ethernet)
3
1 FAIL System software indicates at least one Ethernet link session is down (SOME
UP).
1. Isolate downed sessions (status port UUCSSpp or status link n).
2. Follow actions based on session information.
2 FAIL System software indicates all Ethernet sessions are down (ALL DOWN).
1. Test the port (test port UUCSSpp) to verify the Ethernet Local
Looparound Test (#1278) result.
2. If test passes, wait for system software to indicate ALL UP.
3. If the test fails, check the destination and other components in the path.
4. If the destination and other components in the path are in-service, take
action based on sess ion information.
PASS All sessions are up.
Table 3-271. TEST #1286 Session Status Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page