DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-588DS1-BD (DS1 Interface Circuit Pack)
3
1 to 88 FAIL The DS1 interface circuit pack detected a slip alarm. The error code equals
the number of slips detected by the DS1 interface circuit pac k since the last
slip alarm inquiry test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the DS1 interface circuit pack is a TN767, enter the list measurement
ds1-log UUCSS command to read the error seconds measurement.
3. Verify that both endpoints and all intermediate equipment of the DS1 link
are administered using the same signaling mode, framing mode, and
line coding.
4. If the DS1 interface circuit pack connec ts to a T1 facility, call the vendor
of the T1 carrier to diagnose the remote DS1 endpoint. If the DS1
interface circuit pack connec ts directly to a switch, call the system
technician of the remote switch to diagnose the DS1 endpoint.
5. Check the ac tive alarm and error log s for recent alarms and e rrors
against the synchronization (SYNC). Follow the suggested repair
procedure for these errors.
6. Check the physical connectivity of the DS1 pack and of the c able.
7. If this continues to fail, escalate this problem.
PASS No Slip alarm is detected on the DS1 Interface circuit pack.
0 NO BOARD The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the add
ds1 UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board wa s already administered correctly, check the er ror log to
determine if the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correc tly inserted in step 1, issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the port.
Table 3-245. TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page