DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-386test trunk
2
Output
The following screen is an example of the outp ut for the test trunk 78 command.
The responses display on a test-b y-test basis with one line of data for each test
result.
Field descriptions
Port The port address: cabinet-carrier-slot-circuit
Maintenance
Name The name of maintenance object b eing tested.
Alt. Name The alternate means of identifying the maintenanc e object. If the
object is a trunk, the field contains xxx/yyy (where
xxx
= trunk
group number,
yyy
= member number). If t he object is a private
CO line, the field contains P/xxx (where
xxx
= private CO line
group number).
Test No The test number being exec uted
Result The result of the individual test: PASS, ABORT, FAIL, NO BOARD,
DISABL ED, and EXTRA BD .
Error Code A system-generated numbe r indicating the reason that the test fo r
the named MO failed or abor ted.
test trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 078/001 3 PASS
01C1505 CO-TRK 078/001 36 PASS
Command Successfully Completed