DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-611DS1-BD (DS1 Interface Circuit Pack)
3
2 FAIL The far CSU Loopback Test was not set up properly. The DS1 Interface circuit
pack could not put the far-end CSU into loopbac k mode.
3 FAIL The far CSU Loopback Test was not set up properly. The framed 3-in-24 test
pattern, generated by the DS1 Interface circuit pack and looped back through
the far-end CSU, could not be detected by the DS1 circ uit pack.
1. Retry
t
est ds1-loop UUCSS far-csu-loopback-test-begin.
2. If the Far CSU Loopback test continues to fail with this error code, the
problem could be with the TN767E board, the far-end CSU equipment, or
somewhere in between. Run test ds1-loop UUCSS
cpe-loopback-jack-test-begin to see if the CPE Loo pback Jack test which
is closer to the TN767E board is successful. (If a CPE Loopback Jack
device is not being used, then run test ds1-loop UUCSS
ds1/csu-loopback-tests to see if these even closer loopback tests
succeed). If the closer loopback test fails, follow the maintenance strategy
associated with that loopback
PASS The Far CSU Loopback test has successfully began executing. The test will
continue to run until the system technician enters test ds1-loop UUCSS
end-loopback/span-test or the release board UUCSS.
0NO
BOARD The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrec t
board is inserted , or an insane board is inserte d.
1. Check to ensure that the board translations are correct. Use the add ds1
UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the port.
Table 3-252. TEST #1213 Far CSU Loopback Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page