DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands

2-338test environment

2
3. EXT-DEV tests external (AUDIX, for example) alarm status for both the SCC and MCC cabinet systems.4. RING_GEN tests ringing voltage are tested in MCC ca binets only.
NOTE:
The processor carrier is not be recycled. All p ort carriers are recycled , and service is interrupted for each port carrier. If a carrier containing an active tone-clock board is recycled, all p orts in the cabinet or p ort network will have service disrup ted.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test environment
location
short
long
repeat
number
clear
schedule
Cabinet 1 = PPN
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestruc tive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and then a
scheduling form disp lays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test environment
test environment schedule
test environment 1 sh
test environment 1 l r 25
test environment 01 l r 25
test environment 01 l r 25
schedule
test environment 2 l c
test environment 3 c
1 If no alarms are registered against the maintenanc e object then the test sequence is run only once. The
long clear
option
forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears alarms pertinent
to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Cabinet = 1;
test sequence
= short; repeat
= 1
See below