DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-337test environment
2
Output
The following example shows the output for the test external-device-alarm all
command. The responses d isplay on a test-by-test b asis with one line of data for
each test result.

Field definitions

test environment
This command performs hard ware diagnostic tests of the environment
monitoring and control, and emergency transfer func tions of the Processor Port
Network (PPN) cabinet. Circuit pac ks involved are the Processor (PPN simplex
systems) and the Duplication Inter face circuit p acks. The tone/clock circ uit pack
is involved in tests of the ring g enerator.
There are 8 Maintenance Objects involved in this testing:
1. CABINET tests air flow and temperature
2. EMG-XFER tests emergency transfer status
Port Port address (cabinet-c arrier-slot-circuit)
Maintenance Name The name of the maintenance object
Alt. Name The alternate means of identifying the maintenanc e object, in
this case, the administered (descriptive) name of the external
device alarm.
Test No The test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Error Code Numeric code exp laining why the release failed or ab orted.
Refer to the detailed list of the cod es by test number for eac h
MO.
test eda-external-device-alarm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
Command successfully completed