DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-217ATM-SGRP (ATM Signaling Group)
3
Layer 2 Status Test (#647)
The Layer 2 Status Test checks the layer 2 status of the ATM-SRG Signaling
Channel (D-channel). This test fails when:
there is a hardware failure
there is a facility problem
the D-channels are not administered c orrectly
The Signaling Link Hardware Check (Test #637) and the Remote Layer 3 Query
Test (#1291) detects most problems caused by hardware failures or incorrect
administration.
Table 3-91. TEST #647 Layer 2 Status Query Test
Error
Code
Test
Result Description/ Recommendation
1132 ABORT Internal system error. The port location for the D-channel is not known. This
condition should not be possible since an administered ATM circ uit pack
must be specified when a Signaling Group is administered:
1. Retry the command at one minute intervals a maximum of five times.
1134 ABORT Internal system error. The associated ATM circuit pack is not administered.
This condition should not be possible, since an administered ATM circuit
pack must be specified when administering a Signaling Group.
1. Retry the command at one minute intervals a maximum of three times.
2500 ABORT Internal system error
1. Retry the command at one minute intervals a maximum of five times.
1 FAIL Layer 2 of the signaling channel is down
1. Examine the results of the Signaling Test (#636) and follow
recommendations provided there.
2. If Test #636 (Primary S i gnaling Link Hardware Check) passes, the Layer
2 Query test may still fail if the Signaling Channel at the far end has not
been administered correctly or if the Signaling Channel has been
busied out.
3. Verify that the Signaling Channel (D-channel) at the far end has been
administered correctly.
4. Verify that the ATM-DCH port used for the D-channel has not been
busied out at the far end.
Continued on next page