DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-363CLAN-BD (Control LAN Circuit Pack)
3
1
2
FAIL
FAIL
The buffer level is nearly exhausted.
The CLAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals, up to 5 times.
2. If command continues to fail, examine the CLAN port measurements to
determine which ports are heavily utilized and the processor occupanc y
of the circuit pac k.
Low processor occupancy
when CLAN congested indicates circ uit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupanc y
indicates the CLAN is congested due to traffic
load.
1. To relieve congestion in the short term, selectively busyout ports (busyout
port UUcSSpp) on the Control LAN circuit pack.
2. To achieve a more permanent resolution, it may be necessary to move
ports on this circuit pack to other Control LAN circuit pac ks.
3. Consider replacing affected CLAN ports with new ports.
3 FAIL The CLAN circuit pack is not operating normally and is congested.
PASS Hardware setting and attached cab le type match CLAN circuit pack
administration. The circuit pack detects no errors.
Table 3-160. TEST #600 Congestion Query Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page