DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-205set options
2
Output
The following example shows the output from the save tra nslation command.
Error Codes are as follows:
0 - save successful
1 - could not write to the ac tive device
2 - could not write to the standb y device
Field descriptions
set options
This command enables a remote user with INADS per mission to select which
types of maintenance cat egories report alarms automatic ally and which types
require customer call-in. Jud icious use of this command can reduce the numb er
of ineffective alarms to the TSC. For effective results, technicia ns should use the
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
save
translations spe-active Translations saved on the
active processor’s MSS
device.
init
inads
craft
cust
none If translation
data changes
due to
administrative
commands,
save
translation
cannot be
performed.
Processor Identifies the processor c arrier where translation data is
saved . (SPE-A )
Command
Completion Status Displays a variety of messages, identifying the su ccess
or failure of the command.
save translation
SAVE TRANSLATION
Processor Command Completion Status Error Code
SPE-A Success 0
Command Successfully Completed