DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-61display errors
2
Output
The following examples shows the output from the display disabled-tests
command.
display errors
The display errors c ommand creates an Alarm Repor t. The user completes an
option screen to select the p arameters for the report.
The system creates the reports from the logs of the maintenan ce subsystem. The
subsystem monitors the system hardware and log s problems as errors or alarms.
Errors can result from in-line firmware errors, periodic tests, failures detected
while executing a test comm and, software inconsistency, or a data aud it
discrepancy.

System Reboots and the Error Logs

The system saves the alarm and error logs to the mem ory card if any of the
following events occur:
—The
save translation command is exec uted.
Translations are saved as part of scheduled maintenance.
A reboot takes place.
The PPN is about to lose all power after having been on battery backup .
The attempt to save the alarm and error logs m ay be unsuccessful if the MSS is
not available.
display disabled-tests SPE A
DISABLED TEST INFORMATION
Test Number
710
Command successfully completed