DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-305status system
2
Output
The following example shows the output from the status sy stem all-cabinets
command.
Field descriptions
SPE Switc h Proc ess Ele ment (SPE) id entif ier (1A or 1B)
MODE SPE mode s are d iffe rent for si mple x syst ems t han fo r dup lic ated
systems. See SPE Modes section that follows.
SELECT SWITCH SPE selec t swi tch posi tion:
auto: the switch is in the midd le position and automatica lly
switc hes SPE d epe ndi ng up on c ondi tion s
<blank> al ways appears for the 1A SPE in a simplex system.
PE ALARMS -
MAJOR Number of Major alarms associated with the SPE complex that
affec t the fault seve rity l evel o f this SPE.
SPE ALARMS -
MINOR Number of Minor alarms associated with the SPE complex that
affec t the fault seve rity l evel o f this SPE.
TONE/CLOCK Location of the tone-cloc k circuit pac k (1A and 1B).
SERVICE STATE in: Tone-Clock is installed and is in-service
out: Tone-Clock failed certain maintenance tests and has been
removed from service
<blank> In s implex systems there is no B-carrier Tone-Clock,
and this field displays blank.
status system all-cabinets Page 1 of 3 SPE B
SYSTEM STATUS CABINET 1
SELECT SPE ALARMS TONE/ SERVICE SYSTEM SYSTEM
SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE
1A active 0 2 1A in active active
SERVICE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS
TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS
1A in y n 1 in n n
1B in n y
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-off - CMC
1B