DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-375test station
2
!WARNING:
Since the “clear long ” options clear all c ounters if tests pass, it is p ossible
for firmware counters to be c leared even when a problem exists . In some
cases customer servic e might degrad e since calls may b e routed over
defective equip ment.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test station
extension
short
long
repeat
number
clear
schedule
The station extension (must
conform to dial-plan)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test station 81709 l
test station 85136 s r 2
test station 85036 l r 25
test station 85036 l r 25 schedule
test station 84297 r 4
test station 81709 c
1 If no alarms are registered against the m aintenance object then the test sequenc e is run only once. The
long
clear
option forces a clear of all alarms if no errors are encountered d uring testing. The
short clear
option only
clears alarms pertinent to tests in the short sequence. SEE WARN ING BELO W.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
nms
Test
Sequence
= short;
Repeat =
1
none