DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1101TIE-DS1 (DS1 Tie Trunk)
3
DS1 Tie Trunk Seizure Test (#136)
The DS1 Tie Trunk Seizure Test is run to verify the trunk’s signaling capa bility. The
test is composed of two p arts. The first part queries the c ircuit pack for the
following errors: Loss of Signal, Red Alarm, Blue Alarm, Yellow Alarm, and
Hyperactivity Alarm. The second part of the test is per formed by sending a
seizure message to the DS1 Interface circ uit pack and expec ting an active repl y
by the DS1 Interface circuit pack. If maintenance software d oes not receive any
reply and the timer expires, the test is aborted. Once the ac tive message is
received, a dial p ause message is sent to the DS1 Interface c ircuit pack. If the
DS1 Interface circuit pac k replies with a dial pulse ton e message when the far
end responds to the seizure, then the DS1 tie trunk Seizure Test passes. If the far
end does not respond to the seizure and the timer expires, and the DS1 Interfac e
circuit pack send s a reorder message bac k to the maintenance software, then
the test fails.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test does not run, but it does return PASS. To
verify that the trunk is in-service:
1. Enter status trunk command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release trunk command to put trunk back into in-service.
3. Retry the test command.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to see that there is a valid board inserted.
Table 3-488. TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page