DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-728ISDN-SGR (ISDN-PRI Signaling Group)
3
Table 3-306. TEST #637 Remote Layer 3 Query
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1006 ABORT This is a NORMAL ABORT. For country protocol 1 interfaces (including the
USA), either there are no B-channels administered in this signaling group, or
all B-channels in this signaling group are either out-of-service or are in a
"pending" state (PINS or PMTC, indicating that a B-channel maintenance
message for that B-channel has been sent and not yet acknowledged).
1. Administer an ISDN Trunk or PRI Endpoint Port (B-channel) in this
signaling group, or use the status trunk TRK-GRP/TRK or status
pri-endpoint <extension> command to check the state of the ISDN
Trunks or PR I Endpoint Ports associated with this signaling group. Refer
to ISDN-TRK or PE-BCHL for further details regarding service state
definitions and transitions. For systems not using country protocol 1
interfaces, there are no B-channels administered in this signaling group.
1019 ABORT There is already a Remote Layer 3 Query in progress. This is a normal
ABORT.
1. Wait two minutes, then follow the procedures for when this test passes.
1113 ABORT The Signaling Link is down. Therefore no messages can be sent to the
Far-end switch.
1. Examine the results of Tests #636 and #639 and follow
recommendations provided there.
2. If either test passes, it may be because the signaling link was disabled
by system technician. Verify this by using the display comm link
command. Tests #636 and #639 pass if the signaling link is not enabled.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Same as ABORT with no error code.
1. Follow the recommendations for ABORT with no error code.
2500 FAIL Same as ABORT with no error code.
1. Follow the recommendations for ABORT with no error code.
Continued on next page