DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-854OPS-LINE (DS1 OPS Line)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This is a software audit error that does not indic ate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
b. The DS1OPS Line has been busied out by a busyout station <ext>
command. No calls c an be made on this line.
c. This error type indicates t hat the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interfac e circuit pack.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors log ged
against the DS1 Interface circu it pack. Look for DS1-BD errors in the
Hardware Error Log and follow proced ures provided in the DS1-BD (DS1
Interface Circuit Pack) Maintenanc e documentation.
Table 3-370. DS1 OPS Mai ntenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test station <ext> sh r 1
15 (a) Any Audit and Update
Test (# 36)
18 (b) 0 busyout station <ext> WARNING OFF release station <ext>
130 (c) None WARNING ON test station <ext>
1281 Conference Circuit
Test (# 7) MINOR ON test station <ext> l
1537 NPE Crosstalk Test
(#6) MINOR ON test station <ext> l
1793 (d) test circuit pack PCSS l