DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-349CLAN-BD (Control LAN Circuit Pack)
3
Notes:
a. Error Type 1: Circuit pack stopp ed functioning or is no t physically
present.
1. Verify that the circuit pack is p resent.
2. If circuit pack i s present, reset the circuit pac k (reset board
UUCSS).
3. If the error persists, replace the c ircuit pack.
b. Error Type 18: The CLAN circuit pack bus ied out.
c. Error Type 217: applies to 10 circ uit packs:
1. Remove the circuit pack(s) ag ainst which the error is logg ed.
d. Error Type 257: Transient communication problem between switc h and
circuit pack; d oes not affect service and c an be ignored.
1. Ignore this error, unless the Control Channel Loop Test (#52) fails.
2. If Test #52 fails, replace the circuit pack .
Repetitive failures of the Control Channel Loop Test indicate circ uit pack
hardware failure.
e. Error Type 513: Circuit pack detec ted and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
3842 (t)
3844 (u) Any
3845 (v) Any
3846 (w) Any
3848 (x) Any
3849 (y) Any
3850-
3861 (z) Any
3862 (aa) Any
Table 3-153. CLAN-BD E rror Log EntriesContinued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page