DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-259AXA12-RS/ADX8D-RS/AXD12-RS (AUDIX Reserve Slots)
3
AXA12-RS/ADX8D-RS/AXD12-RS (AUDIX Reserve Slots)
There are no tests associated with these MOs. Both the test board and busy out
board commands abort when eith er is attempted on a reserved slo t. An error
message indicates that the slot is a ssociated with the circ uit pack that the TN568
is emulating, but the requested operation is not valid. If there are errors log ged
against these maintenance ob jects, see XXX-BD .
The TN568 circuit pack connec ts to the switch through a sing le slot in the
backplane; however, the numb er of slots physically oc cupied b y the circuit pac k
is supplied b y the board when inserted. The TN568 is 2 slots wide: the func tional
slot and a reserve slot. The reserve (blank) slot to the left of the functional slot is a
place holder on the swit ch and has no interactio n with the switch.
These MOs are place holders for the extra slot needed for the DEFINITY AUDIX
board. Each instance of these MOs rep resents a reserve slot associated with the
respective circuit p ack mode in whic h the TN568 (DEFINITY AUDIX) is working.
They are used for embedded AUDIX and emulation of respective p ort types.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run Full Name of MO
AXA12-RS NONE NONE TN568 12-port analog
reserve slot
ADX8D-RS NONE NONE TN568 8-port digital reserve
slot
AXD12-RS NONE NONE TN568 12-port digital
reserve slot