DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1026TBRI-BD (TN2185 ISDN Trunk-Side BRI)
3
Notes:
a. The circuit pack stop ped functioning or is physically removed from the
system.
NOTE:
This alarm logs approximately 11 min utes after removing the circuit
pack and/or the SAKI Sanity Test (#53) fails.
If the circuit pac k is not in the system, insert a circuit p ack in the same slot
as the error indicates. See note (g).
b. Transient communication problems b etween the switch and this c ircuit
pack. Execute the test board PCSS command and refer to the repair
procedures for the Control Channel Loop Around Test (#52).
c. On-board hardware failure. Aux data values correspond t o the following
detected errors:
Reset the circuit pack with the busyout board PCSS and re set board
PCSS commands. When reset, the circuit p ack executes a set of tests to
detect the presenc e of any of the faults listed above. Detec tion of one of
these errors during initialization c auses the circuit pac k to lock-up and
appear insane to the system. See the repair p rocedure in Note (a).
d. The circuit pack detects a program log ic error. While no action is required ,
this error can lead to other errors agains t this circuit pack.
3840(l) 4096
to
4101
3842 (m) 46095
3843 (n) 46097
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error
Table 3-454. TBRI-BD Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page