DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-42Restoring Power
1
Restoring Power
The procedures you need to restore p ower depend on the system configuration.
Before performing these ac tivities, refer to the appropriate p rocedure. Restore
power as follows:
1. Plug in power cords in p ort cabinets first.
2. Make sure that the translation card is p roperly inserted into the slot.
3. The system now goes through the rebooting process.The translations are
loaded from the translation card , and rebooting takes ab out 3 minutes.
4. When system power is restored, the approp riate display is shown on the
administration terminal.
The display is the same as a reset system 4.
5. Reset the time using the set time command. Use display time c ommand
to verify.

Power Up the AUDIX System

If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatic ally.
2. Check fro SUCIX System errors.
If the AUDIX remained in the cabinet, bu t power was removed from the cabin et:
1. Power up the cabinet. The AUDIX reboots automatic ally.
2. Check fro AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet

was not

powered down:
1. At the AUDIX console, hold the crtl key down and enter cc.
2. Enter 5 at the prompt. In about 2 minuted the AUDIX boots up .
3. When the system initialization is complete, log in as craft.
4. Check for AUDIX System errors.

Replacing the Power Supply

1. Pull on the latch for the 650A Power Supply.
2. Replace the power supp ly and secure the latch.