DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-815MET-LINE (MET Line)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. Indicates a defective data link. An off-board problem detected by port
circuit. Make sure the MET set is connected, and that the EPF test passes.
If data transmission problems are exp erienced, check for d efective wiring,
check for a defective voice terminal, and move voice terminal closer to the
switch (in terms of feet of wire from the jack to the switch). If problem still
exists, replace the circ uit pack. Once the problem has b een resolved, the
alarm is retired due to the passi ng of time.
b. This error is logged when the por t in question is busied out by
maintenance personnel. Make sure p ort is released from busyout.
Table 3-353. MET Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 b usyout port PCSSpp WARNING OFF release port PCSSpp
130 (c) None WARNING ON test port PCSSpp sh
257 (d) 40988 None MIN/WRN2
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
OFF
513 (e) 40965 Hybrid Line Station
Audits Test (#61) WARNING OFF test port PCSSpp sh r 4
769 Port Diagnostic Test
(#35) MIN/WRN2ON test port PCSSpp l r 3
1025 Hybrid & Conf.
Circuits Test (#57) MIN/WRN2ON test port PCSSpp l r 3
1537 (f) 40968 None MIN/WRN2OFF
1793 TDMNPE Crosstalk
Test (# 6) MIN/WRN2ON test port PCSSpp l r 3
2049(g) 32770
2049(h) 40967
3840(i) 40989