DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1269VC-DSPPT
3
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the reset
procedure, the VC-DSPPT will execute a series of self- tests on the hardware. If
these self- tests fail, the test will fail; otherwise the test will p ass.
Before executing the test, the VC-DSPPT must be busied out by exec uting the
busy port PCSSpp command. After the comp letion of the test, the VC-DSPPT
must be released by exec uting the release port PCSSpp command .
Table 3-542. TEST #1106 VC Port Reset DSP Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available, or the port may
be busy with a call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1015 ABORT The VC-DSPPT is not busied out.
1. Busy out the VC-DSPPT by executing the busy port PCSSpp command
and then retry the test.
2000 ABORT Response to the test was not received from the VC-DSPPT within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this result occurs again, replace the circuit p ack.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT Could not allocate the necessary resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
PASS The VC-DSPPT was su cces sfully reset .
1. Release the VC-DSPPT by executing the reset port PCSSpp
command.
Continued on next page