Maintenance Objects
3-415CONFIG (System Configuration)
3
CONFIG (System Configuration)
The System Configuration maintenance objec t (MO) oversees logical inser tion
and removal of circuit p acks in the system. When Switch Control detects that a
circuit pack is present in a port slot, it informs System Config uration and System
Configuration queries the c ircuit pack to deter mine the type and vintage of the
circuit pack. Similarly, when Switch Control detec ts that a circuit pac k has been
removed from a port slot, it informs System Config uration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This error indicates that a Port circuit p ack in the system did not resp ond
to a circuit pac k type inquiry. Follow the procedures outlined in (c) to
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circui t pack in the system did not respond
to a vintage inquiry.
As a result of either of these errors, a Port circuit pa ck may be physic ally
inserted in a Port slot, but the system may not rec ognize it.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
CONFIG none none System Configuration
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any none
2-117(a) 0-2 none
257(b) none
1002-1117(c) 0-2 none