DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-596DS1-BD (DS1 Interface Circuit Pack)
3
CSU Equipment Loopback Test (#1210)
This test is destructive.
The CSU Equipment Loopback (ELB) Test causes a loopbac k at the near-edge of
the local 120A CSU Module or T1 Sync Spilitter, and tests the c onnection from the
TN767E DS1 board to the CSU Module/T1 Sync Splitter (DS1 board edge
interconnecting c able, and CSU Module/T1 Sync Splitter edge) . This test will only
be performed if the 120A CSU Module/T1 Sync Splitter is present, administered ,
and connected to a 1.544Mbps TN767E DS1 circuit pack on the b ack of the port
carrier.
The test is destructive and c an only be initiated by a sys tem technician
demanded test ds1-loop UUCSS ds1/csu-loopback-tests c ommand.
All trunks or ports on the DS1 Interface c ircuit pack must be b usied out via the
system technician busyout board command before running the ELB Test.
When the ELB Test is initiated, maintenance software sends an appropriate
message to the TN767E DS1 Interface circuit p ack to start the test. The board
sets up the ELB loopback, tra nsmit a test pattern, and verify that the p attern is
received unaltered through the loop back. If the transmitted and received pattern
is different, the test fails.
0NO
BOARD The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrec t
board is inserted , or an insane board is inserted .
1. Check to ensure that the board translations are correct. Use the add ds1
UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the port.
Table 3-248. TEST #1209 DS1 Board Loopback Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page