DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-28ADX16A-PT (AUDIX Analog Line/Control Link)
3
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was p resent when ringing was attemp ted.
Execute the short test port PCSSpp command.
b. The circuit pac k has been logically administered but not p hysically
installed. The alarm will be cleared when the circuit pac k is installed.
c. The circuit pac k has been removed or has been insane for more than 11
minutes. To clear the error, reseat or replace the circuit p ack.
d. This is an in-line error and can only b e resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog c ircuit pack in the
system has this problem, replac e the circuit pac k. If all analog circ uit
packs have this error, chec k the ringing g enerator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to
DEFINITY AUDIX System Maintenance
, 585-300-110.
f. The TD M bus is out of servic e. See the “TDM-BUS” section.
Table 3-11. DEFINITY AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40977 None
18 0 b usyout station
<
extension
>WRN ON release station
extension
23 (b) 0 No ne WRN OFF
130 (c) None WRN ON test port PCSSpp sh
257 (d) 40973 None
513 (e) Any None
1025 (f) Loop Around Test
(#161) MIN/
WRN2
2. Minor alarms on this MO may be dow n g raded to Warning alarms b ased on the values used in the
set options command.
ON test port
PCSSpp
l r 2
1281 Conference Test (#7) MIN/
WRN2ON test p ort
PCSSpp
l r 2
1537 NPE Crosstalk Test (#6) MIN/
WRN2ON test p ort
PCSSpp
l r 2