3-32ADX16A-PT (AUDIX Analog Line/Control Link)

3
Loop Around Test (#161)

This test is designed to ch eck the on-board transmission c apabilities of the NPE

on the analog port.

1018 ABORT Test disabled by administration. This only applies to analog stations.
1. To enable the test for the analog station being tested, enter the change
station <extension> command and chan g e the ‘‘Test?’’ field on the
Station Form from ‘‘n’’ to ‘‘y.’’
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This causes
noisy and unreliable connections.
1. Replace the c ircuit pac k.
PASS The port can correctly conference multiple connec tions. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
Table 3-14. TEST #161 Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources for this test. Try (a).
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port PCSSpp command to determine
the station extension. Use the status station command to d etermine the
service state of the port. If the port is in use, wait until it is idle before testing.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, try (a).
Continued on next page
Table 3-13. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/Recommendation