Maintenance Objects

3-36ANL-24-L (24-Port Analog Line)

3
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line err ors and can only be resolved over time.
40960 indicates that too many simultaneous i ncoming ringing
attempts were made on this board . Only 4 ports on a board may ring simultaneously. A 5th incoming ca ll will cause an inline error from the board.
40975 indicates that the terminal eq uipment was on-hook when
ring-tip was detec ted during ring ing. This usually indicates a fail ure in the terminal equipment or the typ e of terminal has a low ringer
Table 3-15. 24-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test (#36)
18 0 busy-out station
extension
WRN ON release station
<extension>
130(c) None WRN ON test port PCSSpp sh
257(d) 40973 none
513(e) Station Present
Test (#48) WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35) MIN/
WRN2
2. Minor alarms on this MO may be dow ngraded to Warning alarms based on the values used in the set
options command.
ON test port PCSSpp sh r 2
1025 Looparound Test
(#161) MIN/
WRN2ON test port PCSSpp l r 2
1281 Conference Test
(#7) MIN/
WRN2ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6) MIN/
WRN2ON test port PCSSpp l r 2
Continued on next page